Search Results
71
Products for "firestop"
Filter

- Description
- Preformed firestop blocks for sealing penetrations with cables
- Dimensions (LxWxH)
- 8 x 5 x 2 in
- LEED VOC
- 5 g/l
- Storage and transportation temperature range
- 32 - 104 °F

- Description
- High-performance intumescent firestop sealant
- LEED VOC
- 9 g/l
- UL Green Guard Gold
- Yes
- Base materials
- Concrete, Metal, Wood, Drywall

- Description
- Universal fire caulk, providing a flexible firestop seal for fire-rated joints and through penetrations
- LEED VOC
- 49.5 g/l
- Base materials
- Concrete, Masonry, Drywall
- Application temperature range
- 35 - 104 °F

- Description
- Reusable intumescent firestop solution for permanent or temporary cable openings in walls and floors
- Approx. Density
- 0.27 g/cm³
- LEED VOC
- 4.9 g/l
- Storage and transportation temperature range
- 23 - 104 °F

- Description
- Firestop mortar to help prevent fire and smoke from spreading through large openings and load-bearing applications
- Cured density - range
- 56 - 62 lb/ft³
- Storage and transportation temperature range
- 40 - 95 °F
- Application temperature range
- 40 - 113 °F

- Description
- Accessories for CFS-BL / CP 648 / CP 675 Firestop systems
No technical data available

- Description
- Preformed firestop solution for bottom-of-wall drywall joints – increases productivity at the jobsite and eliminates the need for slow, messy sealants
- Approvals
- UL 2079
- Length
- 72 in
- Application
- Joints

- Description
- Stud- or surface-mounted gangplate to increase the capacity of firestop speed sleeves and simplify cable management
- Maximum wall thickness
- 300
- Product Class
- Ultimate
- Application temperature range
- 23 - 122 °F

- Description
- Firestop Preformed solution for top-of-wall drywall joints under metal deck – eliminates the need for slow, messy stuff-and-spray firestop
- Length
- 120 in
- Application
- Joints
- Movement
- Yes

- Description
- Retrofit cable pathway device for firestopping existing cable applications
- Surface burning characteristics UL 723 (ASTM E84)
- Flame spread: 10<BR>Smoke development: 15
- LEED VOC
- 4.9 g/l
- Product Class
- Ultimate

- Description
- Thin stainless steel firestop composite sheet ideal for sealing large openings
- Base materials
- Concrete, Concrete over metal deck, Concrete block, Drywall
- Application temperature range
- -22 - 118 °F
- Storage and transportation temperature range
- -22 - 118 °F

- Description
- Firestop Preformed solution for top-of-wall drywall joints – eliminates the need for slow, messy caulk
- Approvals
- UL 2079
- Length
- 120.5 in
- Application
- Joints

- Description
- Retrofit firestop collar with a galvanized steel housing for 8" and 10" pipes
- Base materials
- Concrete, Drywall, Masonry
- LEED VOC
- 7.6 g/l
- Expansion ratio (unrestricted, up to)
- 1:17

- Description
- BS and UL compliant, FM approved retrofit firestop collar to help create a fire and smoke barrier around existing pipe penetrations
- Base materials
- Concrete, Drywall, Masonry
- LEED VOC
- 7.6 g/l
- Expansion ratio (unrestricted, up to)
- 1:17

- Description
- Self-adhesive discs of firestop putty for single cables, conduits and bundles in openings up to 1"
- Approx. Density
- 1.6 g/cm³
- Color
- Red
- Surface burning characteristics UL 723 (ASTM E84)
- Flame spread: 0<BR>Smoke development: 5

- Description
- Rigid and fast-curing firestop foam with excellent water resistance to help create a fire, smoke and moisture barrier around cable and mixed penetrations
- Application temperature range
- 50 - 86 °F
- Color
- Red
- Content per can/cartridge
- 300 ml

- Description
- Moldable firestop putty to help protect electrical outlet boxes, junction boxes and metallic washer/dryer boxes
- Approx. Density
- 1.6 g/cm³
- Color
- Red
- Surface burning characteristics UL 723 (ASTM E84)
- Flame spread: 15<BR>Smoke development: 10

- Description
- Easy-to-install flexible firestop foam to help create a fire and smoke barrier around for cable and mixed penetrations
- Approx. cure time
- 10 min
- Application temperature range
- 50 - 95 °F
- Color
- Red

- Description
- Easily moldable and reusable firestop putty designed to help create a fire and smoke barrier around cables and metal pipes
- Approx. Density
- 1.6 kg/m³
- Color
- Red
- Surface burning characteristics UL 723 (ASTM E84)
- Flame spread: 15<BR>Smoke development: 10

- Description
- Silicon-based fire caulk, providing a highly flexible firestop seal for construction joints and pipe penetrations
- LEED VOC
- 48 g/l
- Base materials
- Concrete, Masonry, Metal, Gypsum
- Application temperature range
- 35 - 104 °F

- Description
- Easily moldable firestop tape designed to help prevent fire and smoke from spreading through large openings
- Color
- Red
- Surface burning characteristics UL 723 (ASTM E84)
- Flame spread: 15<BR>Smoke development: 10
- LEED VOC
- 2 g/l

- Description
- One-step firestop cast-in sleeve for metal pipe penetrations through floors. Place it and forget it
- LEED VOC
- 1.4 g/l
- W-rating
- Yes, with W-rating module
- Application temperature range
- 23 - 122 °F

- Description
- One-step firestop cast-in sleeve for plastic pipe penetrations through floors. Place it and forget it
- LEED VOC
- 1.4 g/l
- W-rating
- Yes, with W-rating module
- Application temperature range
- 23 - 122 °F

- Description
- Low-shrinkage and easy-to-dispense firestop sealant for fire-rated and non-rated bottom of walls
- LEED VOC
- 43.21 g/l
- Base materials
- Concrete, Drywall, Masonry, Metal
- Application temperature range
- 35 - 104 °F

- Description
- Intumescent, flexible firestop wrap strip to help create a fire and smoke barrier around combustible pipe penetrations
- Base materials
- Concrete, Masonry, Gypsum
- LEED VOC
- 7.6 g/l
- Expansion ratio (unrestricted, up to)
- 1:19

- Description
- Solution for renovation of sealed cable penetrations with 100% fill
- LEED VOC
- 5.4 g/l
- Diameter
- 5-29/32 in
- Storage and transportation temperature range
- 23 - 104 °F

- Description
- Pre-cut, intumescent, flexible firestop wrap strip to help create a fire and smoke barrier around combustible pipe penetrations
- Base materials
- Concrete, Masonry, Gypsum
- LEED VOC
- 7.6 g/l
- Expansion ratio (unrestricted, up to)
- 1:19

- Description
- One-step firestop cast-in sleeve for 8" and 10" metal pipe penetrations through floors. Place it and forget it
- LEED VOC
- 0 g/l
- W-rating
- Yes, with sealant
- Application temperature range
- -40 - 120 °F

- Description
- One-step firestop cast-in sleeve for 8" and 10" plastic and insulated metal pipe penetrations through floors. Place it and forget it
- LEED VOC
- 0 g/l
- W-rating
- Yes, with sealant
- Application temperature range
- -40 - 120 °F

- Description
- Intumescent box insert designed to help protect electrical outlet boxes from fire and smoke
No technical data available

- Description
- Platform to simplify the placement of post-drill, cast-in firestop sleeves on corrugated metal decks
No technical data available

- Description
- Identification signage for firestop installations, making them uniquely identifiable for monitoring and inspection purposes using Hilti Documentation Manager software
- Dispenser Category
- N/A

- Description
- One-step firestop cast-in sleeve for metal pipe penetrations through corrugated metal deck slabs
- Application temperature range
- 23 - 122 °F
- Product Class
- Ultimate

- Description
- One-step firestop cast-in sleeve for plastic pipe penetrations through corrugated metal deck slabs
- Application temperature range
- 23 - 122 °F
- Product Class
- Ultimate

- Description
- Conduit sleeve (1" diameter) with bushing and rigid attachment
No technical data available

- Description
- Pathway device for high-traffic cabling with optimal airflow control
- Product Class
- Ultimate
- Application temperature range
- 23 - 122 °F
- Storage and transportation temperature range
- 23 - 122 °F

- Description
- Two-step solution for sealing cable penetrations requiring a sleeved opening
- Surface burning characteristics UL 723 (ASTM E84)
- Flame spread: 10<BR>Smoke development: 15
- LEED VOC
- 4.9 g/l
- Product Class
- Ultimate

- Description
- Silicone-based sealant providing maximum movement in fire-rated joints and pipe penetrations
- LEED VOC
- 38 g/l
- Base materials
- Concrete, Masonry, Metal
- Application temperature range
- 35 - 104 °F

- Description
- Firestop cast-in accessory to use in bathtubs drains
No technical data available

- Description
- One-step firestop cast-in solution for pipe floor penetrations
- LEED VOC
- 0.19 g/l
- W-rating
- Yes, with W-rating module
- Application temperature range
- 23 - 122 °F

- Description
- Firestop Preformed Solution for top-of-wall drywall joints under metal deck – eliminates the need for slow, messy stuff-and-spray firestop
- Length
- 48 in
- Application
- Joints
- Movement
- Yes

- Description
- Firestop Preformed solution for top-of-wall drywall joints under metal deck – eliminates the need for slow, messy stuff-and-spray firestop
- Application
- Joints
- Movement
- Yes
- Product Class
- Ultimate

- Description
- Firestop cast-in accessory to use in bathtubs drains
- LEED VOC
- 1.4 g/l
- Application temperature range
- 23 - 122 °F

- Description
- Cast-in sleeve for firestopping shower and floor drain systems
- LEED VOC
- 1.4 g/l
- Application temperature range
- 23 - 122 °F

- Description
- High-elasticity firestop spray for construction joints in non-fire-rated assemblies
- Chemical basis
- Water-based acrylic dispersion
- Color
- White
- Shelf life
- 12 Months

- Description
- Dispenser/accessories for compatible firestop
- Dispenser Category
- Cartridge foam dispenser

- Description
- Dispenser/accessories for compatible firestop
- Dispenser Category
- Cartridge foam dispenser

- Description
- Installation aid for use with post-drill, cast-in firestop devices for corrugated metal decks
No technical data available

- Description
- Transit frame to hold firestop modules for sealing cable/pipe penetrations through concrete, masonry and steel
- Product Class
- Standard

- Description
- Firestop preformed solution for sealing edge-of-slab joints – high-speed, no-mess, spray-free installation
- Approvals
- Intertek
- Length
- 60 in
- Application
- Other

- Description
- Modular, versatile accessories to adapt CP 680 firestop cast-in devices for use in virtually any slab
No technical data available

- Description
- Modular, versatile accessories to adapt CP 680 firestop cast-in sleeves for use in virtually any slab
No technical data available

- Description
- Transit frames for fitting firestop modules to seal cable/pipe penetrations – can be welded to steel bulkheads and decks
- Cable diameter - range
- 3 - 99 mm
- Temperature resistance range
- -40 - 122 °F
- Free from
- Halogen (halogen content <= 0.1 weight %)

- Description
- Pre- or post-poured firestop cast-in accessory for water containment and riser clamp support for vertical pipe penetrations
No technical data available