New to Hilti Online?Unlock your prices and shop 24/7Register Now

Filter by

15678 Results
15678 Results
15678 Results

15678 Technical documents

  • C-AJ-8178

    (CAD/BIM Typicals / Auto CAD drawing file)

    HVAC line set with max 1-1/4" PVC or CPVC (CP 643N Firestop Collar) (Includes Hollow-Core)

    English

    Download File [274.2 kB]
  • C-BJ-2012

    (Approval document / Penetration)

    Max. 4" PVC or CPVC (AS=1/4") (Hollow Core) (CP 648E wrap insert & FS-ONE MAX)

    English

    Download File [320.7 kB]
  • C-BJ-8027

    (Approval document / Penetration)

    Single HVAC Line set (8" hollow core) (AS=0" to 1-1/2")

    English

  • F-A-1022

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 1" steel, copper, cast iron, steel conduit or EMT (Max. Qty 5) (CP 680-M, P or PX Cast-In Device)

    English

    Download File [217.6 kB]
  • C-AJ-7046

    (Firestop System Details / UL Detail Drawing)

    Max. 32" x 32" sheet metal duct (w/o damper) (AS=1/4" to 1-1/2") (Silicone Sealant & Mineral Wool)

    English

  • C-AJ-2435

    (Approval document / Penetration)

    Max. 4" ABS, PVC or CPVC (AS=0" to 1/2") (CP 648E 1" wrap strip & retaining collar)

    English

    Download File [376.3 kB]
  • C-BJ-0022

    (Firestop System Details / UL Detail Drawing)

    Max. 24" x 12" unsleeved opening with CFS-BL Firestop Block and sheet metal cover plate fastened to steel channel sheathing

    English

    Download File [120 kB]
  • C-BJ-8020

    (Firestop System Details / UL Detail Drawing)

    Multiple bundle of metallic pipes and cables (2 Hour T-rating with Glass Fiber Insulation) (AS=0" to 2")

    English

  • C-AJ-2600

    (Approval document / Penetration)

    Max. 2" Fusiotherm PP plastic pipe (closed or vented) (AS=0" to 5/8") (Includes Hollow-Core)

    English

    Download File [343 kB]
  • C-AJ-8180

    (Firestop System Details / UL Detail Drawing)

    Insulated or non-insulated copper, steel, iron, flexible steel conduit, or cables (single or bundled) (AS Varies) (CP 620 Fire Foam & Mineral Wool)

    English

    Download File [35.8 kB]
  • C-AJ-8099

    (Approval document / Penetration)

    Insulated or non-insulated copper, steel, iron, flexible steel gas lines, cables (single or bundled), or flexible steel conduit (includes Hollow Core) (AS Varies)

    English

  • F-A-0012

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 30" x 12" or 12" diameter blank opening (Min. 4-1/4" mineral wool & 1/4" silicone sealant)

    English

    Download File [192.1 kB]
  • C-AJ-7030

    (CAD/BIM Typicals / Auto CAD drawing file)

    Insulated Flamebar BW11 Coated Fire Rated Ductwork (CP 637 Firestop Mortar) (AS=2")

    English

    Download File [274.1 kB]
  • C-AJ-2468

    (Firestop System Details / UL Detail Drawing)

    Max. 4" diameter Insulated Beverage Lines (PE or PEX) w/ max. 3/4" AB/PVC (AS=3/16" to 1-13/16")

    English

    Download File [138.4 kB]
  • C-AJ-7029

    (Approval document / Penetration)

    Flamebar BW 11 Fire Rated Duct Work (Max. perimeter of 13.3 ft with Max. dimension 40") (CP 637 Firestop Mortar) (AS=2")

    English

    Download File [143.9 kB]
  • C-BJ-3032

    (Approval document / Penetration)

    Blank or Cables (various) through CFS-T Firestop Cable Transit (Max. 100% fill)

    English

    Download File [151.3 kB]
  • C-BJ-2012

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 4" PVC or CPVC (AS=1/4") (Hollow Core) (CP 648E wrap insert & FS-ONE MAX)

    English

    Download File [181.4 kB]
  • C-BJ-1046

    (Approval document / Penetration)

    Max. 4" steel, cast iron, copper, conduit, or EMT pipe (Hollow-Core Floor)

    English

  • W-J-0007

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 36" blank opening

    English

    Download File [225 kB]
  • C-AJ-7123

    (CAD/BIM Typicals / Auto CAD drawing file)

    Max. 24" x 24" steel air or grease duct with 2 layers of 1-1/2" Duct Wrap by Unifrax (AS=1")

    English