Skip to main content
Save up to 70% On select items. Shop now

Cable transit frames and penetration sealing systems

Seal cable penetrations with our modular firestop solutions, designed to create water-, smoke- and gas-tight barriers in energy and industry projects both onshore and offshore.

22 Products

Filter
Transit Frame
Description
Transit frames for fitting firestop modules to seal cable/pipe penetrations – can be welded to steel bulkheads and decks
Cable diameter - range
3 - 99 mm
Temperature resistance range
-40 - 122 °F
Free from
Halogen (halogen content <= 0.1 weight %)
Transit Frame
Description
Transit frames for fitting firestop modules to seal cable/pipe penetrations – with flange for welding or bolting to steel bulkheads and decks
Temperature resistance range
-40 - 122 °F
Free from
Halogen (halogen content <= 0.1 weight %)
Reaction to fire class (EN 13501-1)
E
CFS-T SBF is a metal frame for concrete application, mainly for onshore energy projects


Description
Transit frame to hold firestop modules for sealing cable/pipe penetrations through concrete, masonry and steel
Product Class
Standard
L057325.tif
Description
Transit frames for fitting modules to seal cable/pipe penetrations in concrete walls and floors
Temperature resistance range
-40 - 122 °F
Free from
Halogen (halogen content <= 0.1 weight %)
Transit Frame
Description
Transit frames for fitting modules to seal existing cable/pipe penetrations in concrete walls and floors
Temperature resistance range
-40 - 122 °F
Free from
Halogen (halogen content <= 0.1 weight %)
Transit Block Cable Module
Description
Modules to seal cables/pipes within transit frames in potentially explosive atmospheres
Temperature resistance range
-40 - 167 °F
Free from
Halogen (halogen content <= 0.1 weight %)
Transit Block Fillermodule
Description
Filler modules for sealing unused space within transit frames in potentially explosive atmospheres
Temperature resistance range
-40 - 167 °F
Free from
Halogen (halogen content <= 0.1 weight %)
Sleeve
Description
Sleeves for fitting plugs to seal round cable/pipe penetrations – for use with CFS-T RR and CFS-T RRS plug seals
Temperature resistance range
-40 - 122 °F
Free from
Halogen (halogen content <= 0.1 weight %)
Sleeve
Description
Sleeves with flange for fitting plugs to seal round cable/pipe penetrations – for use with CFS-T RR and CFS-T RRS plug seals
Temperature resistance range
-40 - 122 °F
Free from
Halogen (halogen content <= 0.1 weight %)
module block
Description
Modules to seal cables/pipes within a transit frame when high water- and gas-tightness and fire-resistance are required
Approvals
UL
Temperature resistance range
-40 - 122 °F
Free from
Halogen (halogen content <= 0.1 weight %)
Module block
Description
Filler modules for sealing unused space within transit frames when high water- and gas-tightness and fire-resistance are required
Approvals
UL
Temperature resistance range
-40 - 122 °F
Free from
Halogen (halogen content <= 0.1 weight %)
Plug Seal
Description
Plug seal for fitting modules to seal multiple cables/pipes in round penetrations
Approvals
UL
Temperature resistance range
-40 - 122 °F
Free from
Halogen (halogen content <= 0.1 weight %)
Plug Seal
Description
Plug seal with electromagnetic compatibility for fitting modules to seal multiple cables/pipes in round penetrations
Temperature resistance range
-40 - 122 °F
Free from
Halogen (halogen content <= 0.1 weight %)
Reaction to fire class (EN 13501-1)
E
Plug Seal
Description
Water- and fire-resistant plug seal for sealing single cables/pipes in round penetrations, with up to 120 minutes of fire integrity
Temperature resistance range
-40 - 122 °F
Free from
Halogen (halogen content <= 0.1 weight %)
Reaction to fire class (EN 13501-1)
E
L057311.tif
Description
Modules to seal cables within transit frames which penetrate switch cabinets
Temperature resistance range
-40 - 122 °F
Free from
Halogen (halogen content <= 0.1 weight %)
Reaction to fire class (EN 13501-1)
E
Wedge Compression Unit
Description
Wedge compression kit for quickly and easily forming a tight, effective seal within cable transit frames
Approvals
UL
Temperature resistance range
-40 - 122 °F
Free from
Halogen (halogen content <= 0.1 weight %)
Fixing Anchorplate
Description
Anchor plate sets to secure cable modules within a transit frame and increase pressure-tightness
Approvals
UL
Temperature resistance range
-40 - 122 °F
Free from
Halogen (halogen content <= 0.1 weight %)
Still life image of the CFS-T cable transit wedge puller
Description
Wedge-puller tool to quickly remove the compression wedge when retrofitting additional cables within a transit frame
Temperature resistance range
-40 - 122 °F
Squeezer
Description
Module squeezer to temporarily pre-compress cable modules, creating space to quickly and easily insert a compression wedge
Temperature resistance range
-40 - 122 °F
Wedge Seal
Description
Wedge compression kit for quickly and easily forming a tight, effective seal within cable transit frames in potentially explosive atmospheres
Temperature resistance range
-40 - 167 °F
Anchor plate CFS-T AP 120 EX
Description
Anchor plate sets to secure cable modules within a transit frame in potentially explosive atmospheres
Temperature resistance range
-4 - 167 °F
Casting mould CFS-T CM-6
Description
Casting mold for use as box-out formwork for CFS-T SB transit frames
Temperature resistance range
-40 - 122 °F

Watch: Cable Transit System Installation and Re-Penetration