Cable transit frames and penetration sealing systems
Seal cable penetrations with our modular firestop solutions, designed to create water-, smoke- and gas-tight barriers in energy and industry projects both onshore and offshore
15 Products
Filter

- Description
- Transit frames for fitting firestop modules to seal cable/pipe penetrations – can be welded to steel bulkheads and decks
- Cable diameter - range
- 3 - 99 mm
- Temperature resistance range
- -40 - 122 °F
- Free from
- Halogen (halogen content <= 0.1 weight %)

- Description
- Transit frames for fitting firestop modules to seal cable/pipe penetrations – with flange for welding or bolting to steel bulkheads and decks
- Temperature resistance range
- -40 - 122 °F
- Free from
- Halogen (halogen content <= 0.1 weight %)
- Reaction to fire class (EN 13501-1)
- E

- Description
- Transit frame to hold firestop modules for sealing cable/pipe penetrations through concrete, masonry and steel
- Product Class
- Standard

- Description
- Transit frames for fitting modules to seal cable/pipe penetrations in concrete walls and floors
- Temperature resistance range
- -40 - 122 °F
- Free from
- Halogen (halogen content <= 0.1 weight %)

- Description
- Transit frames for fitting modules to seal existing cable/pipe penetrations in concrete walls and floors
- Temperature resistance range
- -40 - 122 °F
- Free from
- Halogen (halogen content <= 0.1 weight %)

- Description
- Modules to seal cables/pipes within transit frames in potentially explosive atmospheres
- Temperature resistance range
- -40 - 167 °F
- Free from
- Halogen (halogen content <= 0.1 weight %)

- Description
- Filler modules for sealing unused space within transit frames in potentially explosive atmospheres
- Temperature resistance range
- -40 - 167 °F
- Free from
- Halogen (halogen content <= 0.1 weight %)

- Description
- Sleeves for fitting plugs to seal round cable/pipe penetrations – for use with CFS-T RR and CFS-T RRS plug seals
- Temperature resistance range
- -40 - 122 °F
- Free from
- Halogen (halogen content <= 0.1 weight %)

- Description
- Sleeves with flange for fitting plugs to seal round cable/pipe penetrations – for use with CFS-T RR and CFS-T RRS plug seals
- Temperature resistance range
- -40 - 122 °F
- Free from
- Halogen (halogen content <= 0.1 weight %)

- Description
- Modules to seal cables/pipes within a transit frame when high water- and gas-tightness and fire-resistance are required
- Approvals
- UL
- Temperature resistance range
- -40 - 122 °F
- Free from
- Halogen (halogen content <= 0.1 weight %)

- Description
- Filler modules for sealing unused space within transit frames when high water- and gas-tightness and fire-resistance are required
- Approvals
- UL
- Temperature resistance range
- -40 - 122 °F
- Free from
- Halogen (halogen content <= 0.1 weight %)

- Description
- Plug seal for fitting modules to seal multiple cables/pipes in round penetrations
- Approvals
- UL
- Temperature resistance range
- -40 - 122 °F
- Free from
- Halogen (halogen content <= 0.1 weight %)

- Description
- Plug seal with electromagnetic compatibility for fitting modules to seal multiple cables/pipes in round penetrations
- Temperature resistance range
- -40 - 122 °F
- Free from
- Halogen (halogen content <= 0.1 weight %)
- Reaction to fire class (EN 13501-1)
- E

- Description
- Plug seal for sealing single cables/pipes in round penetrations
- Temperature resistance range
- -40 - 122 °F
- Free from
- Halogen (halogen content <= 0.1 weight %)
- Reaction to fire class (EN 13501-1)
- E

- Description
- Modules to seal cables within transit frames which penetrate switch cabinets
- Temperature resistance range
- -40 - 122 °F
- Free from
- Halogen (halogen content <= 0.1 weight %)
- Reaction to fire class (EN 13501-1)
- E