Filter by

System type
Introducing Firestop Selector (Beta)

Find what you are looking for faster with the new Firestop Selector.

Find the exact system faster with Direct Search (e.g., W-L-1054, 1054, W-L …) or Advanced Search to filter by application, unique site conditions, and installation requirements for penetrations and joints. Preview or download systems in full UL, Trade, or DWG detail.

Try it today. .

  • HW-D-0184
    HW-D-0184
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")

    Related products: CP 606 Firestop acrylic sealant , Mineral wool Show all

  • HW-D-0259
    HW-D-0259
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum wall to bottom of fire-proofed steel I-beam to concrete over metal deck (Max. JW=1-1/2")

    Related products: CFS-SP WB Water-based acrylic sealant spray , Mineral wool Show all

  • HW-D-0264
    HW-D-0264
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum wall to concrete over fluted metal deck (top-of-wall) (offset flutes) (Max. JW=1-1/2")

    Related products: CFS-SP WB Water-based acrylic sealant spray , Mineral wool Show all

  • HW-D-0292
    HW-D-0292
    • Joint type: Head-of-Wall
    • Assembly rating:4 Hour
    • Gypsum Wall to concrete over fluted metal roof deck (top-of-wall) (perpendicular) (Max. JW=1")

    Related products: CFS-SP WB Water-based acrylic sealant spray , Mineral wool Show all

  • HW-D-0313
    HW-D-0313
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum wall to concrete over metal deck w/ spray-on fireproofing completely filling flutes and joint (top-of-wall) (Max. JW=3/4")

    Related products: CFS-SP WB Water-based acrylic sealant spray Show all

  • HW-D-0516
    HW-D-0516
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1")

    Related products: CP 606 Firestop acrylic sealant , Mineral wool Show all

  • HW-D-0528
    HW-D-0528
    • Joint type: Head-of-Wall
    • Assembly rating:1 Hour
    • Gypsum wall to insulated roof deck (top-of-wall) (Max. JW=2")

    Related products: CP 606 Firestop acrylic sealant , CFS-S SIL GG Firestop silicone sealant Show all

  • HW-D-0539
    HW-D-0539
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum wall to concrete floor (top-of-wall) (Max. JW=1-1/2")

    Related products: CFS-SP WB Water-based acrylic sealant spray , Mineral wool Show all

  • HW-D-0605 (US Only)
    HW-D-0605 (US Only)
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum wall to concrete or hollow core floor (with max. 2" CPVC pipe through joint) (top of wall) (Max. JW=1")

    Related products: CP 606 Firestop acrylic sealant , CP 648-E firestop endless wrap strips Show all

  • HW-D-0636
    HW-D-0636
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum Shaft Wall to bottom of offset I beam with Z-bar extensions (Max. JW=1-1/2")

    Related products: CFS-SP WB Water-based acrylic sealant spray , Mineral wool Show all

  • HW-D-0654
    HW-D-0654
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum wall to concrete floor or hollow core (top-of-wall) (Max. JW=1")

    Related products: CP 606 Firestop acrylic sealant , Mineral wool Show all

  • HW-D-0687
    HW-D-0687
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum wall to concrete over metal deck (top of wall) (parallel)(cantilevered runner) (Max. JW=1-1/2")

    Related products: CFS-SP WB Water-based acrylic sealant spray , Mineral wool Show all

  • BW-S-0002
    BW-S-0002
    • Joint type: Bottom-of-Wall
    • Assembly rating:4 Hour
    • Gypsum wall to Concrete floor (bottom-of-wall)

    Related products: CP 606 Firestop acrylic sealant , CFS-S SIL GG Firestop silicone sealant Show all

  • HI/BP 120-07 (CEJ 244P)
    HI/BP 120-07 (CEJ 244P)
    • Joint type: Curtain Wall
    • Assembly rating:2 Hour
    • Concrete Panels with Steel Framing (Max. JW=8")

    Related products: CFS-SP WB Water-based acrylic sealant spray , Mineral wool Show all

  • HI/BP 180-02 (CEJ 308P)
    HI/BP 180-02 (CEJ 308P)
    • Joint type: Curtain Wall
    • Assembly rating:3 Hour
    • Glass Spandrel with I-shaped Aluminum Framing (Max. JW=8")

    Related products: CFS-SP WB Water-based acrylic sealant spray , Mineral wool Show all

  • HI/BP 105-01 (CEJ 309P)
    HI/BP 105-01 (CEJ 309P)
    • Joint type: Curtain Wall
    • Assembly rating:1 Hour
    • Glass Spandrel with Aluminum Framing (Max. JW=8")

    Related products: CFS-SP WB Water-based acrylic sealant spray , Mineral wool Show all

  • HI/BP 105-02 (CEJ 310P)
    HI/BP 105-02 (CEJ 310P)
    • Joint type: Curtain Wall
    • Assembly rating:1 Hour
    • Glass Spandrel with Aluminum Framing (I-shaped) (Max. JW=8")

    Related products: CFS-SP WB Water-based acrylic sealant spray , Mineral wool Show all

  • HI/BP 120-03 (CEJ 421P)
    HI/BP 120-03 (CEJ 421P)
    • Joint type: Curtain Wall
    • Assembly rating:2 Hour
    • Gypsum wall with various facades (Max. JW=9", including studs)

    Related products: CFS-SP WB Water-based acrylic sealant spray , Mineral wool Show all

  • CJ-D-0008 (US Only)
    CJ-D-0008 (US Only)
    • Joint type: Continuity Head-of-Wall
    • Assembly rating:1 Hour
    • Gypsum Wall to non-rated insulated roof deck (Max. JW=2")

    Related products: CP 606 Firestop acrylic sealant , CFS-S SIL GG Firestop silicone sealant Show all

  • CW-S-2029
    CW-S-2029
    • Joint type: Curtain Wall
    • Assembly rating:2 Hour
    • Aluminum Spandrel Panel and Aluminum Framing (Max. JW=8")

    Related products: CFS-S SIL SL Firestop silicone sealant , Mineral wool Show all