Documents and video library
Firestop Submittal Generator
Step 1: Firestop System Selection
Search and filter [1078]
Back to results (1078)
Define your requirements
System type
Generate a firestop submittal in 3 easy steps

Step 1: Find an appropriate Firestop System by searching with the system number or by inputting the application characteristics into the filters.
Step 2: Select a system that matches the application by clicking in the system box. Click on the "i" to learn more about the system attributes.
Step 3: Review the selected systems and additional information. When you are satisfied with the information you have chosen, select "Generate Submittal".

  • HW-D-0120  
    • Joint type: Head-of-Wall
    • Assembly rating:3 Hour
    • Gypsum wall (with Fire Trak) to concrete over fluted metal deck or flat concrete (top-of-wall) (Max. JW=1")

    Related products: CP 606 , Mineral wool Show all

  • HW-D-0154  
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")

    Related products: CP 606 , Mineral wool Show all

  • HW-D-0155  
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=3/4")

    Related products: CP 606 , Mineral wool Show all

  • HW-D-0190  
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum wall to concrete over metal deck w/ spray-on fireproofing completely filling flutes (top-of-wall) (Max. JW=2")

    Related products: CFS-SP WB , Mineral wool Show all

  • HW-D-0209  
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum wall to concrete floor or hollow core (top-of-wall) (Max. JW=1")

    Related products: CP 606 , CFS-S SIL GG Show all

  • HW-D-0225  
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Concrete or block wall to concrete over fluted metal deck (top-of-wall) (Max. JW=2-1/4")

    Related products: CP 606 , Mineral wool Show all

  • HW-D-0258  
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Concrete or block wall to concrete over fluted metal deck with structural steel beams or bar joists penetrating wall (top-of-wall) (Max JW=1")

    Related products: CFS-SP WB , Mineral wool Show all

  • HW-D-0264  
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum wall to concrete over fluted metal deck (top-of-wall) (offset flutes) (Max. JW=1-1/2")

    Related products: CFS-SP WB , Mineral wool Show all

  • HW-D-0268  
    • Joint type: Head-of-Wall
    • Assembly rating:3 Hour
    • Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=1") (backer rod optional)

    Related products: CP 606 , Mineral wool Show all

  • HW-D-0292  
    • Joint type: Head-of-Wall
    • Assembly rating:4 Hour
    • Gypsum Wall to concrete over fluted metal roof deck (top-of-wall) (perpendicular) (Max. JW=1")

    Related products: CFS-SP WB , Mineral wool Show all

  • HW-D-0294  
    • Joint type: Head-of-Wall
    • Assembly rating:4 Hour
    • Concrete or block wall to concrete over fluted metal deck (top-of-wall) (perpendicular) (Max. JW=1")

    Related products: CFS-SP WB , Mineral wool Show all

  • HW-D-0295  
    • Joint type: Head-of-Wall
    • Assembly rating:4 Hour
    • Gypsum Wall to concrete over fluted metal roof deck (top-of-wall) (parallel) (Max. JW=1")

    Related products: CFS-SP WB , Mineral wool Show all

  • HW-D-0296  
    • Joint type: Head-of-Wall
    • Assembly rating:4 Hour
    • Concrete Wall to concrete over fluted metal roof deck (top-of-wall) (parallel) (Max. JW=1")

    Related products: CFS-SP WB , Mineral wool Show all

  • HW-D-0313  
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum wall to concrete over metal deck w/ spray-on fireproofing completely filling flutes and joint (top-of-wall) (Max. JW=3/4")

  • HW-D-0324  
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum Wall to concrete over fluted metal roof deck (top-of-wall) (perpendicular) (Max. JW=3/4")

    Related products: CP 606 , Mineral wool Show all

  • HW-D-0342  
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum shaft wall to concrete floor (Max. JW=1")

  • HW-D-0388  
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum wall to concrete over metal deck with one side inaccessible due to structural member (Max. JW=1-1/2")

    Related products: CFS-SP WB , Mineral wool Show all

  • HW-D-0389  
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Concrete or block wall to concrete over metal deck with one side inaccessible due to structural member (Max. JW=1")

    Related products: CFS-SP WB , Mineral wool Show all

  • HW-D-0396  
    • Joint type: Head-of-Wall
    • Assembly rating:2 Hour
    • Gypsum wall to concrete over fluted metal roof deck (offset to flute) (Max. JW=3/4")

    Related products: CFS-SP WB , CP 606 Show all

  • HW-D-0403  
    • Joint type: Head-of-Wall
    • Assembly rating:3 Hour
    • Concrete or block wall to concrete floor joint (top-of-wall) (Max. JW=2")

    Related products: CP 606 , Mineral wool Show all